BIS U-4A7-082- _1C-07-S4
Industrial RFID system - Read/write head
7
Startup and operation (continued)
Data
The data read out is displayed in the d
The left area of the data field shows the start addresses of
the individual lines. The center area shows the data in
hexadecimal format. The right area shows the ASCII
representation of the data. Data to be written can be
edited directly in the data field by keyboard input (in hex or
ASCII format).
Manipulate data
For simple data values, the buttons i
c
and f
can be used. In the S
ontinuouS
ixed vaLue
v
field, a start value for the c
aLue
value for the f
function can be specified.
ixed vaLue
Load/save data
Via the buttons o
or S
, the hex data of the data field
Pen
ave
can be exported to a file (*.dat) or imported from a file.
7.2.6

Parameter setting

Depending on the active security level, various settings can
be made under P
... and a
arameterS
The meaning of the individual parameters and their
assignment to the UHF Manager are described in
Requirement data on page 28.
The S
biS and r
end to
eceive from
to transfer the parameters to or read them from the read/
write head.
The S
... and o
... buttons can be used to save the
ave aS
Pen
parameter sets in an xml file or to read them in from an xml
file. This procedure simplifies the parameterization if several
devices are to receive the same parameterization.
The Default settings button initially only resets the user
interface to the values of the delivery state. The
S
biS button can be used to transfer the parameters
end to
to the read/write head.
www.balluff.com
field.
ata
, d
,
ncrement
ecrement
/
tart vaLue
function or a
ontinuouS
....
dvanced ParameterS
biS buttons can be used
7.3
Operation
CAUTION
Ultra high frequency electromagnetic waves
The antenna of the read/write head emits ultra-high-
frequency electromagnetic waves. Additional measures
must be taken to prevent health hazards.
► Determine the mounting position of the antenna in
such a way that a safety distance of at least 20 cm
between the antenna and workplaces of persons is
ensured.
► Make sure that people do not stay in the vicinity of
the antenna for an extended period of time.
► Use suitable measures to shield areas that are
explicitly not to be covered.
If Pin 2 is used as switching output, observe the
maximum current limit
(See Technical data on page 79).
7.4

Operating notes

Check the function of the UHF RFID read/write head
and all connected components regularly.
In the event of malfunctions, take the UHF RFID read/
write head out of operation.
Secure the system against unauthorized use.
Check fasteners and retighten if needed.
7.5

Cleaning

The UHF RFID read/write head can be cleaned with a
high-pressure cleaner. The device cannot reliably access
data carriers during cleaning.
All ECOLAB cleaning agents can be used to remove dirt.
To avoid damaging the front cap of the read/write head
during the cleaning process, use a soft cloth, but do not
use rough materials.
7.6

Maintenance

The product is maintenance-free.