Herunterladen Inhalt Inhalt Diese Seite drucken

Command Identifier 0X40: Select Data Carrier (Select); Command Identifier 0X41: Unselect Data Carrier (Unselect) - Balluff BIS U-4A7-082-01C-07-S4 Betriebsanleitung

Industrial rfid-system – schreib-/lesekopf
Vorschau ausblenden Andere Handbücher für BIS U-4A7-082-01C-07-S4:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

BIS U-4A7-082- _1C-07-S4
Industrial RFID system - Read/write head
8
System integration (continued)
8.7.4
Command identifier 0x40: Select data carrier
(Select)
The Select command can be used in multi-tag mode to
select a single data carrier within a data carrier population.
A data carrier that is located in the active read/write range
of the antenna is addressed and selected directly on the
basis of its EPC or TID and is then available for further
processing.
Command:
Subaddress Meaning
0x00
1st bit string
0x01
Command
recognition
0x02
Type EPC/
TID
0x03
Number of
bytes
0x04
Reserved
0x05
Reserved
0x06
Reserved
...
None
0x1F
2nd bit
string
Data is accepted from the processor unit only after the
command has been accepted by the processor unit and
acknowledged.
Data:
Subaddress Meaning
0x00
1st bit string
0x01
Data
...
Data
...
None
0x1F
2nd bit
string
www.balluff.com
Functional description
0x40: Select Tag (selection
of data carrier).
EPC = 0
TID = 1
Number of bytes of the
data carrier identifier (EPC
or TID) that are
transmitted in following
cycles.
Set to 0.
Set to 0.
Set to 0.
No meaning
If the 1st and 2nd bit
strings match, valid data is
present.
Functional description
1st byte of the data carrier
identifier (EPC or TID)
Other bytes of the data
carrier identifier (EPC or
TID)
No meaning
If the 1st and 2nd bit
strings match, valid data is
present.
8.7.5
Command identifier 0x41: Unselect data
carrier (Unselect)
The Unselect command can be used to cancel a data
carrier selection that was made with the Select command.
If no selection is active, the status remains unchanged.
Command:
Subaddress Meaning
0x00
1st bit string
0x01
Command
recognition
...
None
0x1F
2nd bit
string
Input buffer: Status message
Response:
Subaddress Meaning
0x00
1st bit string
0x01
Status code
...
None
0x1F
2nd bit
string
Functional description
0x41: Unselect (cancel
data carrier selection).
No meaning
If the 1st and 2nd bit
strings match, valid data is
present.
Functional description
Provides information
about the status of a
request.
No meaning
If the 1st and 2nd bit
strings match, valid data is
present.
english
47

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis