BIS U-4A7-082- _1C-07-S4
Industrial RFID system - Read/write head
8
System integration (continued)
10. Bulk Write
Write to all data carriers located in front of the antenna.
Write 32 bytes starting from data carrier address 3.
Controller
1.
Process output buffer
(note sequence):
0x01
Command recognition 0x54
0x02
Start address 0x03
0x03
Start address 0x00
0x04
Number of bytes 0x20
0x05
Number of bytes 0x00
0x06
Data carrier selection
0x07
Max Tags 0xFF
0x00/0x1F
Set AV bit
3.
Process output buffer:
0x01...0x1E
Enter first 30 bytes
0x00/0x1F
Invert TI bit
5.
Process output buffer:
0x01...0x02
Enter last 2 bytes
0x00/0x1F
Invert TI bit
7.
Process input buffer:
0x01
Copy number of tags found
0x02
Copy number of successfully written tags
Process output buffer:
0x00/0x1F
Reset AV bit
www.balluff.com
Identification system
2.
Process input buffer
(note sequence):
0x00/0x1F
Set AA bit, invert TO bit
4a.
Process output buffer:
0x01...0x1E
Copy first 30 bytes
4b. Process input buffer:
0x00/0x1F
Invert TO bit
6a.
Process output buffer:
0x01...0x02
Copy last 2 bytes
6b. Process input buffer:
0x01
Enter number of tags found
0x02
Enter number of successfully written tags
0x00/0x1F
Set AE bit
8.
Process input buffer:
0x00/0x1F
Reset AA and AE bits