8
System integration (continued)

8.7.10 Command identifier 0x50: Kill

Permanently disables a selected data carrier and locks it to
prevent any use. To execute the kill command, a kill
password must first be set and written to the data carrier.
A kill command permanently disables the
selected data carrier and cannot be
undone!
Details on password protection and locking and
unlocking (Lock) of UHF RFID data carriers can
be found in the EPC
Protocols Generation-2 UHF RFID standard.
Command:
Subaddress Meaning
0x00
1st bit string
0x01
Command
recognition
0x02
Password 1
0x03
Password 2
0x04
Password 3
Password 4
(High Byte)
...
None
0x1F
2nd bit
string
Response:
Subaddress
Meaning
0x00
1st bit string
0x01
Status code
...
None
0x1F
2nd bit
string
www.balluff.com
Radio-Frequency Identity
TM
Functional description
0x50 : Kill
1st byte password
2nd byte password
3rd byte password
4th byte password
No meaning
If the 1st and 2nd bit
strings match, valid data is
present.
Functional description
Provides information
about the status of a
request.
No meaning
If the 1st and 2nd bit
strings match, valid data is
present.