BAE SA-OH-063-_P-DP02 / BAE SA-OH-063-_P-S75G
Photoelectric Sensors
4
Product description (continued)
4.1
Construction
The electrical connection is made via a cable or plug
connection (see Type code on page 17).
4.2
Function
The sensor amplifier serves as a processor unit for Balluff
sensors of the BOH series.
4.3
Operating and display elements
The settings of the amplifier can be changed via the control
panel with the status LEDs.
Teach mode switch (TEACH)
Switch mode switch
Delay switch
Teach+ button
Teach− button
Fig 4-2:
Control panel of the amplifier
4.3.1
Operating elements
Switch
Switch
Position
Function
Dark on
Low active
Switch
mode
Light on
High active
Aut
Automatic teach
Teach mode
(TEACH)
Man
Manual teach
On D
50 ms switch-on delay
Delay
Off
No delay
Off D
50 ms switch-off delay
Tab. 4-1:
Switch
www.balluff.com
Power LED (PWR)
Output LED (OUT)
Buttons
Teach
Button
Function
mode
Press for 1...2.5 s: Set
1-point teach
Aut
Hold down for 3.5...30 s: Set
Teach+
Auto teach
Increase amplification factor/
Man
range
Press for 1...30 s: Set 2-point
teach
Aut
Press again to end 2-point
Teach−
teach
Man
Reduce amplification factor
Tab. 4-2:
Buttons
4.3.2
Display elements
LED
Function
Green,
Device ready
static
Power LED
Green
Signal value in hysteresis
(PWR)
flashing
Teach successful
Red, static Error
Yellow,
Switch output switched
Output LED
static
(OUT)
Off
Switch output not switched
Tab. 4-3: Display elements
4.4
Labeling
1)
Order code
1)
Alternatives Anschlussbild:
Type
2)
3)
Serial number
1 - brown +VDC
Fig 4-3:
Labeling (example)
2 - blue
GND
3 - black
OUT NPN
4 - white
EXT TEACH
2)
3)
english