Herunterladen Inhalt Inhalt Diese Seite drucken

Balluff BIS U-4A7-082-01C-07-S4 Betriebsanleitung Seite 156

Industrial rfid-system – schreib-/lesekopf
Vorschau ausblenden Andere Handbücher für BIS U-4A7-082-01C-07-S4:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

BIS U-4A7-082- _1C-07-S4
Industrial RFID system - Read/write head
8
System integration (continued)
11. Bulk Read
Read from all data carriers located in front of the antenna.
Read 4 bytes from data carrier address 3 in case 4 data
carriers are found.
Controller
1.
Process output buffer
(note sequence):
0x01
Command recognition 0x53
0x02
Start address 0x03
0x03
Start address 0x00
0x04
Number of bytes 0x04
0x05
Number of bytes 0x00
0x06
Data carrier selection
0x07
Max Tags 0xFF
0x00/0x1F
Set AV bit
3.
Process input buffer:
0x01
Copy number of tags found 0x04
0x02
Copy number of bytes per tag 0x04
0x03
Copy number of bytes per tag 0x00
0x04...0x07
Copy 4 bytes of data of first tag
0x08
Read check byte of first tag
0x09...0x0C
Copy 4 bytes of data of second tag
0x0D
Read check byte of second tag
0x0E...0x11
Copy 4 bytes of data of third tag
0x12
Read check byte of third tag
0x13...0x16
Copy 4 bytes of data of fourth tag
0x17
Read check byte of fourth tag
Process output buffer:
0x00/0x1F
Reset AV bit
72
english
Identification system
2.
Process input buffer
(note sequence):
0x00/0x1F
Set AA bit
0x01
Enter number of tags found 0x04
0x02
Enter number of bytes per tag 0x04
0x03
Enter number of bytes per tag 0x00
0x04 ...0x17
Enter 20 bytes of data
0x00/0x1F
Set AE bit
0x00/0x1F
Invert TO bit
4.
Process input buffer:
0x00/0x1F
Reset AA bit
0x00/0x1F
Reset AE bit

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis