Herunterladen Inhalt Inhalt Diese Seite drucken

Installing Cooling Fan - Dell EMC PowerEdge R740xd2 Installations- Und Servicehandbuch

Vorschau ausblenden Andere Handbücher für EMC PowerEdge R740xd2:
Inhaltsverzeichnis

Werbung

Abbildung 34. Disconnecting fan 1 cable from PIB connector
Nächste Schritte
Replace the cooling fans.

Installing cooling fan

Voraussetzungen
1. Follow the safety guidelines listed in
2. Power off the system and all attached peripherals.
3. Disconnect the system from the electrical outlet, and disconnect the peripherals.
4. Ensure that all internal cables are routed correctly and connected, and no tools or extra parts are left inside the system.
5.
Open the drive
bays, remove
6. Remove the
power supply
7. Remove the system from the rack and place it on an ESD work bench. For more information, see the Schieneninstallationshandbuch
unter www.dell.com/poweredgemanuals.
8.
Remove the system
cover.
9.
Remove the air
shroud.
10.
Remove the internal PERC
11. Move the cables out of the way to access the cooling fan cable connector on the system board.
Schritte
1. Lower the cooling fan into the cooling fan cage, until the blue release tab clicks into place.
2. Route the cable through the cable retention tabs.
3. Connect the power cable to the connector on the system board.
ANMERKUNG:
If installing cooling fan 1, connect the fan cable connector to the power interposer board (PIB).
Safety
instructions.
all
drives, and then
close the drive bays.
units.
riser.
Installing and removing system components
61

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis