Herunterladen Inhalt Inhalt Diese Seite drucken

Rear Drive Cage; Removing The Rear Drive Cage - Dell EMC PowerEdge R740xd2 Installations- Und Servicehandbuch

Vorschau ausblenden Andere Handbücher für EMC PowerEdge R740xd2:
Inhaltsverzeichnis

Werbung

Abbildung 56. Installing the bay intrusion switch
Nächste Schritte
1.
Install the drive bay 1
bracket.
2.
Close the drive bays.
3. If removed,
install the front bezel.
4. Follow the procedure listed in

Rear drive cage

Removing the rear drive cage

Voraussetzungen
1. Follow the safety guidelines listed in
2. Power off the system and all attached peripherals.
3. Disconnect the system from the electrical outlet, and disconnect the peripherals.
4.
Open the drive
bays, remove
5. Remove the
power supply
6. Remove the system from the rack and place it on an ESD work bench. For more information, see the Schieneninstallationshandbuch
unter www.dell.com/poweredgemanuals.
7.
Remove the system
cover.
8.
Remove the air
shroud.
9.
Remove the rear drives.
10. Disconnect all the cables from the rear drive backplane.
Schritte
1. Using Phillips #2 screwdriver, loosen the screws that secure the drive cage to the system.
2. Disengage the rear drive cage from the chassis by pushing it towards the front of the system and lift the drive cage away from the
system.
80
Installing and removing system components
After working inside your
Safety
instructions.
all
drives, and then
close the drive bays.
units.
system.

Werbung