Status
Link indicator is blinking green, and activity is off.

Power supply unit indicator codes

AC power supply units (PSUs) have an illuminated translucent handle that serves as an indicator. The indicator shows whether power is
present or if a power fault has occurred.
Abbildung 146. AC PSU status indicator
1. AC PSU status indicator/handle
Tabelle 47. AC PSU status indicator codes
Power indicator codes
Green
Blinking amber
Not illuminated
Blinking green
Blinking green and turns off When hot-plugging a PSU, the PSU handle blinks green five times at a rate of 4 Hz and turns off. This
174
System diagnostics and indicator codes
Condition
A valid power source is connected to the PSU and the PSU is operational.
Indicates a problem with the PSU.
Power is not connected to the PSU.
When the firmware of the PSU is being updated, the PSU handle blinks green.
VORSICHT:
Do not disconnect the power cord or unplug the PSU when updating firmware.
If firmware update is interrupted, the PSUs do not function.
indicates a PSU mismatch with respect to efficiency, feature set, health status, or supported voltage.
VORSICHT:
If two PSUs are installed, both the PSUs must have the same type of label; for
example, Extended Power Performance (EPP) label. Mixing PSUs from previous generations
of PowerEdge servers is not supported, even if the PSUs have the same power rating. This
results in a PSU mismatch condition or failure to power on the system.
VORSICHT:
When correcting a PSU mismatch, replace only the PSU with the blinking
indicator. Swapping the PSU to make a matched pair can result in an error condition and
unexpected system shutdown. To change from a high output configuration to a low output
configuration or vice versa, you must power off the system.
VORSICHT:
AC PSUs support both 240 V and 120 V input voltages with the exception of
Titanium PSUs, which support only 240 V. When two identical PSUs receive different input
voltages, they can output different wattages, and trigger a mismatch.
VORSICHT:
If two PSUs are used, they must be of the same type and have the same
maximum output power.