Option
Description
Serial Port
Enables you to set the port address for serial devices. This field sets the serial port address to either COM1 or
Address
COM2 (COM1=0x3F8, COM2=0x2F8). This option is set to Serial Device1=COM2 or Serial Device 2=COM1
by default.
External Serial
Enables you to associate the External Serial Connector to Serial Device 1, Serial Device 2, or the Remote
Connector
Access Device by using this option. This option is set to Serial Device 1 by default.
Failsafe Baud Rate Specifies the failsafe baud rate for console redirection. The BIOS attempts to determine the baud rate
automatically. This failsafe baud rate is used only if the attempt fails, and the value must not be changed. This
option is set to 115200 by default.
Remote Terminal
Sets the remote console terminal type. This option is set to ANSIVT100/VT220 by default.
Type
Redirection After
Enables or disables the BIOS console redirection when the operating system is loaded. This option is set to
Boot
Enabled by default.

Systemprofileinstellungen

Mit dem Bildschirm System Profile Settings (Systemprofileinstellungen) können Sie spezifische Einstellungen zur Systemleistung wie
die Energieverwaltung aktivieren.
Viewing System Profile Settings
To view the System Profile Settings screen, perform the following steps:
Schritte
1. Power on, or restart your system.
2. Press F2 immediately after you see the following message:
F2 = System Setup
ANMERKUNG:
If your operating system begins to load before you press F2, wait for the system to finish booting,
and then restart your system and try again.
3. On the System Setup Main Menu screen, click System BIOS.
4. On the System BIOS screen, click System Profile Settings.
System Profile Settings details
Info über diese Aufgabe
The System Profile Settings screen details are explained as follows:
36
Pre-operating system management applications
ANMERKUNG:
You can use only Serial Device 2 for the Serial Over LAN (SOL) feature. To use
console redirection by SOL, configure the same port address for console redirection and the serial
device.
ANMERKUNG:
Every time the system boots, the BIOS syncs the serial MUX setting saved in
iDRAC. The serial MUX setting can independently be changed in iDRAC. Loading the BIOS default
settings from within the BIOS setup utility may not always revert the serial MUX setting to the
default setting of Serial Device 1.
ANMERKUNG:
Only Serial Device 2 can be used for Serial Over LAN (SOL). To use console
redirection by SOL, configure the same port address for console redirection and the serial device.
ANMERKUNG:
Every time the system boots, the BIOS syncs the serial MUX setting saved in
iDRAC. The serial MUX setting can independently be changed in iDRAC. Loading the BIOS default
settings from within the BIOS setup utility may not always revert this setting to the default
setting of Serial Device 1.