Removing The Processor - Dell EMC PowerEdge R740xd2 Installations- Und Servicehandbuch

Vorschau ausblenden Andere Handbücher für EMC PowerEdge R740xd2:
Inhaltsverzeichnis

Werbung

5. Remove the
power supply
6. Remove the system from the rack and place it on an ESD work bench. For more information, see the Schieneninstallationshandbuch
unter www.dell.com/poweredgemanuals.
7.
Remove the system
cover.
8.
Remove the air
shroud.
9. If installed,
remove the rear drive
10. If installed,
remove the
Schritte
1. Using a Torx #T30 screwdriver, loosen the screws on the heat sink in the order below:
a) Loosen the first screw three turns.
b) Loosen the second screw completely.
c) Return to the first screw and loosen it completely.
2. Pushing both blue retention clips simultaneously, lift the processor and heat sink module (PHM) processor and heat sink module.
3. Set the PHM aside with the processor side facing up.
Abbildung 75. Removing a processor and heat sink module
Nächste Schritte
Replace a processor and heat sink

Removing the processor

Voraussetzungen
ANMERKUNG:
Only remove the processor from the processor and heat sink module if you are replacing the processor or
heat sink. This procedure is not required when replacing a system board.
1. Follow the safety guidelines listed in
2. Power off the system and all attached peripherals.
3. Disconnect the system from the electrical outlet, and disconnect the peripherals.
4.
Open the drive
bays, remove
units.
cage.
risers.
module.
Safety
instructions.
all
drives, and then
close the drive bays.
Installing and removing system components
99