The object directory

8.5 List of encoTRive parameters

The following is a list of all the encoTRive parameters arranged in parameter number order. Each
parameter is specified in the form
PNU
Name
where
PNU
Parameter number
1-899 => encoTRive specific parameter
900-999 => PROFIdrive profile parameters; these are parameters, which stand in
connection with communication via PROFINET.
Name
Parameter designation
Attribute
Information in the form:
Access/Flash memory/Factory setting/Password protected/PZD configuration
Access: rw – read/write: Parameter can be read and written,
Flash- memory:
Factory setting:
Password protected: s
PZD configuration:
Data type
Data type according to Table 25 page 195 for simple parameters.
For arrays: Array[NumberElements] Data type of the array elements
Default
Value which is pre-set in the factory.
Minimum value, whereby in case of "**"internally a dynamic change occurs
Min
(see chapter 8.5.1.3, 8.5.1.18, 8.5.1.19)
Maximum value, whereby in case of "**"internally a dynamic change occurs
Max
(see chapter 8.5.1.3, 8.5.1.18 and 8.5.1.19)
 TR-Electronic GmbH 2008, All Rights Reserved
Page 198 of 252
Attribute
Data type
ro – read only: Parameter is write-protected
f
Parameter is stored in Flash on a 0/1 transition of the
value of Parameter 971.
-
Parameter is not stored in Flash
w
Parameter is preset to the default value when the
factory settings are loaded
-
(Parameter 970: 1/0 transition)
Value is not preset to the default value
Parameter can only be written after the password
has been enabled.
p
Parameter can be mapped in the PZD telegram
TR - EMO - BA - DGB - 0019 - 08
Default
Min
Printed in the Federal Republic of Germany
Max
06/06/2019