Herunterladen Inhalt Inhalt Diese Seite drucken

Table 8: Status Word P968 (Zsw) - TR-Electronic MP-Series Benutzerhandbuch

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Bit
Value Significance
1
Ready to switch on
0
0
Not ready to switch on
1
Ready for operation
1
0
Not ready for operation
1
Run enabled
2
0
Run inhibited
1
Fault
3
0
Fault free
1
No OFF 2
4
0
OFF 2
1
No OFF 3
5
0
OFF 3
1
6
Switch-on inhibit
0
No switch-on inhibit
1
Warning
7
0
No Warning
8
Specific to operating mode
1
9
Command required
0
Local operation
10
Specific to operating mode
11
Specific to operating mode
12
Specific to operating mode
13
Specific to operating mode
14-15
Not used

Table 8: Status word P968 (ZSW)

Printed in the Federal Republic of Germany
06/06/2019
Description
Power supply switched on, electronics initialized. Main
contactor de-energized, if applicable, pulses inhibited.
Ready for operation. Voltage on converter.
Enable electronics and pulses
Fault present. Drive in "Fault" state.
OFF 2 command present.
OFF 3 command present.
Drive continues to run; Warning present and can be seen
from P953. No acknowledgement
The control system is requested to take over command
Only local control possible
TR - EMO - BA - DGB - 0019 - 08
 TR-Electronic GmbH 2008, All Rights Reserved
Page 169 of 252