8.4 Saving the object directory in flash / Factory settings

When the encoTRive is switched on, the object directory is initially preloaded with the
factory settings. If the flash memory contains a valid image of the object directory,
then the object directory is overwritten with this image. Otherwise, the factory settings
will be retained.
Changes to the object directory in the flash can be made during operation by
changing the value of Parameter 971 from 0 to 1. The values stored in this way are
used in the next run-up. The object directory can be reloaded with the factory settings
by changing the value of Parameter 970 from 1 to 0. These can be stored in flash by
means of Parameter 971.