CAUTION!
Exiting medium!
If KH4 is open, the medium exits uncontrollably from the ball valve. This may lead to injury or material damage.
► Assume a protected position.
► Only open ball valves slowly.
► Securely collect the medium.
4.
Remove the NeoFlow pressure reducing valve. Use tools suitable for the removal and make sure that there is no mechanical
strain on the piping system.
A
ATTENTION!
Exiting medium!
The remaining medium between the shut-off valves A and O in the piping system may exit uncontrollably from the piping system
when removing the NeoFlow pressure reducing valve.
► Shut off the the shut-off valves on the inlet and outlet (A and O) in advance.
► Reduce the pipe pressure in advance.
► Assume a protected position.
► Securely collect the medium.
S
D
NeoFlow pressure reducing valve
N
H
O