BRKT
PTT UNIT
L (G)
G (L)
PTT UNIT
SERVICE POINTS
PTT fluid filling
1. Fill:
Reservoir
Recommended PTT fluid:
ATF Dexron II
NOTE:
Fully extend the tilt rod when filling the res-
ervoir with the fluid.
2. Install:
Reservoir plug
Reservoir plug:
7.0 Nm (0.7 m • kg, 5.2 ft • lb)
Air bleeding
1. Bleed:
PTT unit
Bleeding steps:
Close the manual valve by turning it
clockwise.
Set the PTT unit upright.
Connect the PTT motor leads to the
battery.
Tilt rod
Up
Remove the reservoir plug and make
sure the PTT fluid is up to the brim of
the reservoir plug hole. If the PTT fluid
is below the brim of the reservoir plug
hole, add fluid until it is to the proper
level.
Install the reservoir plug.
Connect the PTT motor leads to the
battery.
Tilt rod
Down
7-38