Herunterladen Diese Seite drucken

Siemens SIMATIC S7-200 Systemhandbuch Seite 404

Vorschau ausblenden Andere Handbücher für SIMATIC S7-200:

Werbung

S7-200 Systemhandbuch
;================================================
; GSD File for the EM 277 PROFIBUS-DP with a DPC31
; MLFB
; DATE
;================================================
#Profibus_DP
;General parameters
GSD_Revision
Vendor_Name
Model_Name
Revision
Ident_Number
Protocol_Ident
Station_Type
FMS_supp
Hardware_Release
Software_Release
9.6_supp
19.2_supp
45.45_supp
93.75_supp
187.5_supp
500_supp
1.5M_supp
3M_supp
6M_supp
12M_supp
MaxTsdr_9.6
MaxTsdr_19.2
MaxTsdr_45.45
MaxTsdr_93.75
MaxTsdr_187.5
MaxTsdr_500
MaxTsdr_1.5M
MaxTsdr_3M
MaxTsdr_6M
MaxTsdr_12M
Redundancy
Repeater_Ctrl_Sig
24V_Pins
; Slave-Specification:
OrderNumber="6ES7 277-0AA2.-0XA0"
Periphery="SIMATIC S5"
Slave_Family=10@TdF@SIMATIC
Freeze_Mode_supp
Sync_Mode_supp
Set_Slave_Add_Supp
Auto_Baud_supp
Min_Slave_Intervall
Fail_Safe
Max_Diag_Data_Len
Modul_Offset
Modular_Station
Max_Module
Max_Input_len
A
Max_Output_len
Max_Data_len
; UserPrmData-Definition
ExtUserPrmData=1 "I/O Offset in the V-memory"
Unsigned16 0 0-10239
EndExtUserPrmData
; UserPrmData: Length and Preset:
User_Prm_Data_Len=3
User_Prm_Data= 0,0,0
Max_User_Prm_Data_Len=3
Ext_User_Prm_Data_Const(0)=0x00,0x00,0x00
Ext_User_Prm_Data_Ref(1)=1
Bild A-27
394
: 6ES7 277-0AA2.-0XA0
: 26-March-2001
= 1
= "Siemens"
= "EM 277 PROFIBUS-DP"
= "V1.02"
= 0x089D
= 0
= 0
= 0
= "1.00"
= "1.02"
= 1
= 1
= 1
= 1
= 1
= 1
= 1
= 1
= 1
= 1
= 60
= 60
= 250
= 60
= 60
= 100
= 150
= 250
= 450
= 800
= 0
= 2
= 2
= 1
= 1
= 0
= 1
= 1
= 0
= 6
= 0
= 1
= 1
= 128
= 128
= 256
GSD-Datei des EM 277 PROFIBUS-Moduls
;================================================
; Continuation of GSD File
;================================================
; Module Definition List
Module = "2 Bytes Out/ 2 Bytes In
EndModule
Module = "8 Bytes Out/ 8 Bytes In
EndModule
Module = "32 Bytes Out/ 32 Bytes In
0xC0,0x1F,0x1F
EndModule
Module = "64 Bytes Out/ 64 Bytes In
0xC0,0x3F,0x3F
EndModule
Module = "1 Word Out/ 1 Word In
EndModule
Module = "2 Word Out/ 2 Word In
EndModule
Module = "4 Word Out/ 4 Word In
EndModule
Module = "8 Word Out/ 8 Word In
EndModule
Module = "16 Word Out/ 16 Word In
EndModule
Module = "32 Word Out/ 32 Word In
0xC0,0x5F,0x5F
EndModule
Module = "2 Word Out/ 8 Word In
0xC0,0x41,0x47
EndModule
Module = "4 Word Out/ 16 Word In
0xC0,0x43,0x4F
EndModule
Module = "8 Word Out/ 32 Word In
0xC0,0x47,0x5F
EndModule
Module = "8 Word Out/ 2 Word In
0xC0,0x47,0x41
EndModule
Module = "16 Word Out/ 4 Word In
0xC0,0x4F,0x43
EndModule
Module = "32 Word Out/ 8 Word In
0xC0,0x5F,0x47
EndModule
Module = "4 Byte buffer I/O
EndModule
Module = "8 Byte buffer I/O
EndModule
Module = "12 Byte buffer I/O
EndModule
Module = "16 Byte buffer I/O
EndModule
-" 0x31
-" 0x37
-"
-"
-" 0x70
-" 0x71
-" 0x73
-" 0x77
-" 0x7F
-"
-"
-"
-"
-"
-"
-"
-" 0xB3
-" 0xB7
-" 0xBB
-" 0xBF

Quicklinks ausblenden:

Werbung

loading