Alternate trigger (Trigger Mode: Pulse)
Alternate trigger (Trigger Type: Pulse) Menu is shown as Fig. 46.
Alternate trigger (Trigger Type: Pulse) menu list
MENU
Source
Mode
when
settings
Coupling
Holdoff
Holdoff
Reset
Fig. 46 Alternate trigger (Trigger Type: Pulse) Menu
SETTING
CH1
CH2
Pulse
(+pulse width less than )
(+pulse width more than )
(+Pulse width equal to)
(-Pulse width less than)
(-Pulse width more than)
(-Pulse width equal to)
24ns~10s
AC
DC
HF
LF
100 ns ~ 10 s
INSTRUCTION
Select CH1 as the trigger source.
Select CH2 as the trigger source.
To select pulse width condition
Turn "TRIG LEVEL" knob to set time
Not allow DC portion to pass.
Allow all portion pass.
Not allow high frequency of signal pass and
only low frequency portion pass.
Not allow low frequency of signal pass and only
high frequency portion pass
Turn "TRIG LEVEL" knob to set time slot before
another trigger event
Reset hold time to 100ns
-152-