8. ARRANGEMENT
Tha- S3*
Function
Thermostat a
Thermostat b
DT function
Timer
Reference output
Flow rate
Output
Reference
output
Reference output 1
Reference output 2
Reference output 3
Reference output 4
Reference output 5
RMS
Arrangement / Opt. functions / Add new function / RMS
Adjustment
Description
channel
Mixer op.
Output selection mixer open
Mixer cl.
Output selection mixer closed
Sen. store
Store sensor allocation
Sen. HC ret.
HC return sensor allocation
Sen. boiler ret. Boiler return sensor allocation
Switch-on temperature difference
DTOn
Switch-off temperature difference
DTOff
Set temperature difference
DTSet
TMax
Maximum boiler return temper-
ature
Interval
Mixer interval
Heating circuit Detection controller heating circuit
active
Heating circuit Heating circuit allocation
Runtime
Mixer runtime
Detection
Mixer opening degree
Time
Time of automatic adjustment
Funct.
Activation / Deactivation
Sensor
Switch input selection
This function can be used for heating backup.
Heat from the store is mixed into the heating circuit return by means of a mixing valve in order
to add heat to the heating circuit. The controller compares the temperature at the selected store
sensor to the heating circuit return temperature. If the store temperature exceeds the heating
circuit return temperature by the switch-on temperature difference, the mixer will be used to
add solar heat from the store to the heating circuit return. The mixer will be opened or closed in
pulses depending on this deviation. The mixer will be controlled with the adjustable interval. The
pause is determined by the difference between the actual value and the set value.
Thb-S4*
Timer
DT-S3>S4*
* exemplary selection, sensors and outputs can be freely selected
RX
Reference output 1
Reference output 2
1. in parallel (OR)
Adjustment
range / selection
system dependent
system dependent
system dependent
system dependent
system dependent
1.0 ... 25.0 K
0.5 ... 24.0 K
-20 ... +25 K
10 ... 80 °C
1 ... 20 s
Internal, External
HC 1...7
10 ... 600 s
50 ... 90 %
00:00 ... 23:45
Activated, Deacti-
vated, Switch
-
Fl.rate
R3*
Reference output
Reference output 3
Reference output 5
Reference output 4
2. in series (AND)
Factory setting
system dependent
system dependent
system dependent
system dependent
system dependent
5.0 K
3.0 K
+15 K
60 °C
2 s
Internal
-
140 s
60 %
00:00
Activated
-