Installation of Wilo-Smart Con-
nect module BT
Fig. 26: Wilo-Smart Connect Module BT
Fig. 27: Cover for Wilo-Smart Connect Mod-
ule BT
9

Installation of CIF module

Installation and operating instructions • Wilo-Stratos GIGA2.0-I, Wilo-Stratos GIGA2.0-D • Ed.02/2022-07
The following tools are required: Allen key, hexagon wrench, torx wrench, Phillips screw-
driver, slotted screwdriver
The Bluetooth interface Wilo-Smart Connect Module BT (Fig. 25, Item 3, and Fig. 26) is used
to connect to mobile end devices such as smartphones and tablets. The Wilo-Smart Connect
feature is in the Wilo-Assistant app. Using the Wilo-Smart Connect feature, you can operate
and adjust the pump and read out pump data. For settings, see "Commissioning" [} 162] sec-
tion.
Technical data
Frequency band: 2400 MHz ... 2483.5 MHz
Maximum radiated transmission power: < 10 dBm (EIRP)
Installation
DANGER
Risk of fatal electrical shock!
Immediate risk of fatal injury if live components are touched!
• Check whether all connections are voltage-free!
1.
Loosen the four screws of the upper part of the electronic module (Fig. 25, Item 1; Fig. I,
Item 2).
2.
Remove the upper part of the electronic module and put it aside.
3.
Insert the Wilo-Smart Connect Module BT into the designated interface Wilo-Con-
nectivity Interface. See Fig. 25, Item 3.
4.
Refit the upper part of the electronic module!
If the Wilo-Smart Connect Module BT is only to be checked, the upper part of the electronic
module can remain installed. To carry out a check, proceed as follows:
1.
Loosen the screw of the Wilo-Smart Connect module cover (Fig. 27) and open the cover.
2.
Check Wilo-Smart Connect Module BT.
3.
Close the cover again and fasten it with the screw.
Due to its design, the Wilo-Smart Connect Module BT can only be plugged in in one align-
ment. There is no further fixing of the module itself. The Wilo-Smart Connect module cover
(Fig. 27) on the upper part of the electronic module holds the module firmly in the interface.
Observe the tightening torques! Tightening torques for electronic module [} 160]
CAUTION
IP55 protection is only guaranteed if the Wilo-Smart Connect Module BT
cover is installed and screwed tight!
DANGER
Risk of fatal electrical shock!
Immediate risk of fatal injury if live components are touched!
• Check whether all connections are voltage-free!
CIF modules (accessories) are used for communication between pumps and building man-
agement systems. CIF modules are plugged into the electronic module (Fig. 25, Item 4)
For twin-head pumps, only the main pump must be equipped with a CIF module.
For pumps in Y-pipe applications in which the electronic modules are connected to each
other through the Wilo Net, only the main pump also requires a CIF module.