Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data; Dimensions, Weights, Ambient Conditions; Supply Voltage (External); Control Signals - Balluff BTL5-S1 M HB-FA F C-Serie Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
BTL5-S1_ _-M_ _ _ _-HB/WB-FA_ _/F_ _-C
Micropulse Linear Transducer - Rod Style
8

Technical Data

Typical values at DC 24 V, room temperature and BTL with nominal length of 500 mm. Ready for operation at once,
full accuracy after warm-up. With magnet BTL-P-1013-4R, BTL-P-1014-2R or BTL-P-1012-4R:
Resolution (LSB)
depending on version:

BTL5-S1 _1...

1 µm
BTL5-S1 _2...
5 µm
BTL5-S1 _3...
10 µm
BTL5-S1 _4...
20 µm
BTL5-S1 _5...
40 µm
BTL5-S1 _6...
100 µm
BTL5-S1 _7...
2 µm
BTL5-S1 _8...
50 µm
Non-linearity
for resolution < 10 µm
for resolution > 10 µm
Output data
Update rate f
max
Hysteresis
Repeatability
(resolution + hysteresis)
Temperature coefficient
< (6 µm + 5 ppm * nominal length)/K
lag error
2.5 Frame
Shock loading
100 g/6 ms
1
per EN 60068-2-27
Continuous shock
100 g/2 ms
1
per EN 60068-2-29
Vibration
12 g, 10 to 2000 Hz
per EN 60068-2-6
1
(take care to avoid inherent reso-
nances of protective tube)
Pressure
up to 600 bar
when installed in a
hydraulic cylinder
1
Individual specifications as per
Balluff factory standard
8.1
Dimensions, weights,
ambient conditions
Nominal length
< 5500 mm
➥ ➥ ➥ ➥ ➥ Fig. 3-1
Dimensions
Weight
approx. 2 kg/m
Housing/Flange
Stainless steel
1. 4404
Pressure tube
Stainless steel
1.4571
Diameter
10.2 mm
Wall thickness
2 mm
E-modulus
approx. 200 kN/mm
Mounting threads
M18×1.5 or 3/4"-16UNF
Operating temp.
–40 °C to +85 °C
Humidity < 90 %, non-dewing
Protection rating per IEC 60529
with connector attached:
cable version
IP 68
(type tested at 5 bar / 48 h)
IP69/K with connected cable guard
system
8.2

Supply voltage (external)

Regulated supply voltage
BTL5-_1...
Ripple
Current draw
Inrush
Polarity reversal
protection
Overvoltage protection
Transzorb diodes
Electric strength
± 30 µm
GND to housing
± 2 LSB
8.3

Control signals

< 2 kHz
Interface
< 1 LSB
Clock input:
< 2 LSB
(via optical coupler)
Clock frequency
Output data
Position
information
2004/108/EC (EMC Directive)
and the EMC Law. Testing in our
EMC Laboratory, which is accred-
ited by DATech for Testing Elec-
tromagnetic Compatibility, has
2
confirmed that Balluff products
meet the EMC requirements of
the following Generic Standards:
EN 61000-6-1 (noise immunity)
EN 61000-6-2 (noise immunity)
EN 61000-6-3 (emission)
EN 61000-6-4 (emission)
and the following product standard:
EN 61326-2-3
20 to 28 V DC
< 0.5 V
pp
< 90 mA
< 3 A/0.5 ms
built-in
500 V DC
RS 485/422
+Clk, –Clk
max. 1000 kHz
+Data, –Data
24 or 25 bit
serial
The CE Mark verifies
that our products meet
the requirements of
EU Directive
8.4

Connection to processor

BTL5-...-FA05
with connecting cable,
axial arrangement, 5 m long
BTL5-...-F05
with connecting cable,
radial arrangement, 5 m long
Teflon cable
-40 °C to +200 °C
The clock frequency is a function
of the cable length:
Cable length
Clock frequency
< 25 m
< 1000 kHz
< 50 m
< 500 kHz
< 100 m
< 400 kHz
< 200 m
< 200 kHz
< 400 m
< 100 kHz
Table 8-1: Clock frequency
The following patents have been
granted in connection with this
product:
US Patent 5 923 164
Apparatus and Method for Auto-
matically Tuning the Gain of an
Amplifier
Emission tests:
RF Emission
EN 55016-2-3 (industrial and
residential area)
Noise immunity tests:
Static electricity (ESD)
EN 61000-4-2
Severity level 3
Electromagnetic fields (RFI)
EN 61000-4-3
Severity level 3
Fast transients (Burst)
EN 61000-4-4
Severity level 3
Surge
EN 61000-4-5
Severity level 2
Line-induced noise induced by
high-frequency fields
EN 61000-4-6
Severity level 3
Magnetic fields
EN 61000-4-8
Severity level 4
english
9

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Btl5-s1 m wb-fa f c-serie

Inhaltsverzeichnis