6.

CLEANING DISASSEMBLY AND REASSEMBLY

IMPORTANT
Cleaning and sanitizing are operations that need to be normally carried out at every production
end, with the utmost care to guarantee the quality of production and hygiene standards
necessary.
6.1.

CLEANING

6.1.1. Machines with pump
1. Start the 'wash cycle',
spatula, close the dispenser and select '' off '',
out the pump unit.
2. Unscrew the tank fitting, pour water into the tank and carefully wash all surfaces.
3. Select "wash cycle"
4. Close the dispenser and select '' off ''
5. Perform rinsing with water and sanitize for several cycles "and finish rinsing when the
drain water becomes clean.
6. Unscrew the dispenser knobs, pull out the dispenser and then the beater.
7. Clean the cylinder both inside and outside.
8. Remove the pump unit and the dispensing unit (paragraph 6.3, paragraph 6.2)
9. Wash the components in the dishwasher or manually.
10. Assemble the pump unit with all components and the dispensing unit using the
supplied gasket guide (paragraph 6.3, paragraph 6.2)
11. Insert the beater into the cylinder with its stuffing box (paragraph 6.5)
12. Insert the dispensing unit and tighten the knobs.
13. Screw the fitting into the tank bottom, insert the pump unit and connect the flow tube
6.1.2. Machine in gravity
1. Start the 'wash cycle',
the gravity piston with a spatula, close the dispenser and select 'off',
unscrew the gravity piston.
2. Pour water into the tank carefully washing all surfaces.
3. Select 'wash cycle',
4. Close the dispenser and select '' off ''
5. Rinse with water, sanitize for several cycles, "and finish rinsing when the drain water
becomes clean.
MU0000_0717
drain the remaining product by helping the pump with a
open the dispenser and empty the tank.
drain the remaining product by passing the mixture through
open the dispenser and empty the tank.
77
unhook the flow tube and pull
KLIMAGEL