3.2.

CONDENSATION BY AIR

Air-condensing machines must be installed while maintaining a minimum specific distance per
model indicated within the installation sheet of the corresponding machine (paragraph 3.1)
NOTE
Improper ventilation of the machine effects operation and production capacity
3.3.

CONDENSATION BY WATER

In order to operate, the water condenser machine must be connected to running water or a
cooling tower.
The water inlet must have a pressure of at least 1 Bar and a flow rate at least equal to the
expected time of consuming.
Connect the inlet hose, labeled "Water Inlet" to the water tank by taping a faucet, and the outlet
hose, marked by the "Water Outlet" label, to the drains by taping with a faucet (the connections
are indicated in the model installation sheet of each specific machine paragraph 3.1)

3.3.1. Pressure regulating valve

IMPORTANT
If necessary, take out the pressure valve, this should only be performed by qualified personnel.
The valve adjustment must be carried out in such a way that with the machine stopped no
water comes out and when the machine is in production it is lukewarm water.
NOTE
Water consumption increases if the inlet water temperature in the machine is greater than 20°
Do not leave the machine in areas with temperatures lower than 0 ° C without draining
the condenser circuit (see Section 7 of this manual).
MU0000_0717
CAUTION
65
KLIMAGEL