Herunterladen Inhalt Inhalt Diese Seite drucken

Error And Warning Messages - Balluff BMD 1E NH5-Serie Konfigurationsanleitung

Mikrowellen-positionssensor
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

BMD 1E _ _ - _ _ _ _ / _ _ _ -NH5...
Microwave Positioning Sensor
3
Function (continued)
3.5

Error and warning messages

The sensor distinguishes between error and warning
messages.
Warning messages indicate that the sensor is in a critical
state. In the 0x6505 Warnings-object the various warning
messages can be read out. The BMD CANopen warning
message shows the error codes for the various warning
messages. As soon as the sensor is again in the specified
operating condition, this warning automatically expires. A
warning message is a first indicator of improper use of the
sensor and should be taken seriously.
When an error occurs in the system the position signal is
no longer reliable. When an error occurs multiple times, the
sensor and its surroundings must be thoroughly checked.
For more about error messages see section Emergency
message and error register on page 10.
When an error occurs the position signal is
set to the maximum value (0xFFFF)!
In this state the measurement data are no
longer reliable.
Difference between warning messages:
Error value
0x2000 Temperature Warning 1 The temperature is outside the
0x4000 Temperature Warning 2 The temperature is outside the
0x8000 Close Range
Tab. 3-4:
BMD CANopen warning messages
www.balluff.com
Remarks
specification (–40 °C...+95 °C).
Warning is cleared in the temperature range
–37...+92 °C
specification (–50 °C...+110 °C).
Warning is cleared in the temperature range
–47...+107 °C
The piston is near the lower cylinder stop.
Possible causes
The sensor is operating outside the
temperature specification.
The sensor is operating outside the
temperature specification.
english
9

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis