Description of the inputs:
Input voltage (Input 1- Input 8)
Input impedance
1
2
3
4, 5, 6
7
8
3-bit screen table for stored position:
Input 6
Remark: for more finely defined positioning, the function of the encoder replication or
the RS485 connection can be used.
UP
DOWN
Start initialization run
Move to stored position
94
Input
Input 5
0
0
0
0
0
1
0
1
1
0
1
0
1
1
1
1
When high level is active, movement towards the maximum position
takes place.
When high level is active, movement towards the minimum
position takes place.
MultiControl II duo and MultiControl II quadro assembly instructions
Standard function
High: 5 VDC – 30 VDC
Low: 0 VDC – 2 VDC
10 k Ohm
AUF
AB
Approve the action from the 3-bit screen
(input 4 – 6)
3-bit screen for stored position
Speed (s/l)
Acknowledge error
Input 4
0
1
Drive to memory position 1
0
Drive to memory position 2
1
Drive to memory position 3
0
Drive to memory position 4
1
Drive to memory position 5
0
Drive to memory position 6
1
Drive to memory position 7
when
high
level
an initialization run. After the mode has been set,
initialisation is performed with the UP and DOWN
inputs.
starts the movement towards the memory position
from the table below (description of the outputs).
Position
Start the initialization
is
active,
it
initiates