No.
100
SPP collision detection mode 1: without error, 2: error, 3:
automatic release
101
SPP collision detection mode 3 release distance in
increments
102
Low speed area in increments before end position in
retraction direction. It holds the drive at the set position
when retracting. After pressing the down key again, the
drive continues to move at a reduced speed (par. 14).
103
2-key hand switch stroke reduction in increments. When
moving with the 2-key hand switch, the stroke is shortened
in the extend direction by the configured amount of
increments.
107
Specification of drive type for drive group 2
109
Specification of grouping for the drives. Currently possible:
0 – Drive group management not activated; 2211 – motor
connections 1 & 2 belong to group 1 / motor connections 3
& 4 belong to group 2.
111
Specification of hall sensor conditions from group 1 to
group 2
MultiControl II duo and MultiControl II quadro assembly instructions
Parameter description

6.5.6.15 Reloading the factory settings

With this function, all of the settings can be restored to the factory settings.
• Open the "Control" menu item
• Select the "Reload factory settings" sub-item.
-›› The factory settings are loaded. You will be prompted to start an
initialisation run. Please observe chapter 6.5.4.2 on this.
Default
Min.
(MLII)
1
1
150
0
0
0
0
0
See conf.
10
0
2211
10000
2000
Max.
3
32000
65500
65500
99
2211
60000