Instructions for use for the user
Intensity regulation when the dimmer switch function is deactivated
When the dimmer switch function for the additional output has been deactivat-
ed, you can only switch the additional device on and off. The device will always
operate at full power.
1. Select the additional output symbol 7 by pressing the mode button D. Then
briefly press the On/Off button A.
► The additional device switches on.
► The display 1 shows "on".
Room temperature control with the additional output
If the additional output mode is set to room temperature regulation (see: "Setting
mode of the additional output (Pro D2i / Pro D3i only)" on page 35), a
cabin temperature can be set that is regulated via the additional output. This
can be used to regulate the cabin temperature using only infrared heaters or
infrared heating plates.
Setting options
● Infrared heaters (without foil sensor): 30 - 70° C
● Infrared heating plates (with foil sensor): 30 - 60 °C
If the sauna heater is already active or if it is started additionally, tem-
perature regulation of the additional output is not possible. The mode is
automatically changed to intensity regulation and the additional output
continues operating at the highest level.
Using the optional control panel "Additional output control panel Pro D"
The optional control panel enables the switching on and off of the additional
output as well as the modulation or changing of the temperature. The additional
output can only be activated if the control unit is already switched on.
1. The additional output is switched on and off using the On/Off button A.
► The additional device switches on.
► The display a on the control panel lights up.
2. Set the desired power of the additional output with the plus button B and
the minus button C.
► The set value is displayed in the form of points (see a "9.5. Additional
output control panel Pro D (optional)" on page 40).