Installation instructions, only for experts
4.5. Installing humidity/temperature sensor FTS2 (optional, Pro
D3 / Pro D3i only)
The humidity/temperature sensor must be installed on the wall of the cabin above
the rear bench seat. A distance of approx. 15 cm from the ceiling of the cabin
must be maintained.
To install the humidity and temperature sensor, perform the following steps:
1. Route the 5-pole sensor cable in the wall of the sauna cabin to the mount-
ing position of the humidity/temperature sensor and affix the sensor leads
using cable clips.
2. Install the humidity/temperature sensor to the wall of the sauna cabin using
the two supplied wood screws (16 mm). Maintain a clearance of 15 cm to
the roof of the sauna cabin.

4.6. Installing foil sensor FTS2 (optional, Pro D2i / Pro D3i only)

If one or more infrared heating plates is connected to the additional output, the
foil sensor 1-014-445 / P-ISX-FF must be used:
● When installing and positioning the foil sensor, observe the operating instruc-
tions for the infrared heating plates.
● Use of a foil sensor must be activated in the technician menu (see "Activating/
deactivating the foil sensor (Pro D2i / Pro D3i only)" on page 32).