9. Do not touch any mechanically moving or hot parts.
Do not remove any protective covers.
10. Only original parts may be used for maintenance
and accessories.
11. Repair and adjustment work may only be carried
out by authorised specialist personnel.
12. Protect yourself from electrical hazards.
13. Never touch the power generator with wet hands.
14. Only use approved and appropriately identified ex-
tension cables for use outdoors (H07RN).
15. Never operate the power generator during rain or
snowfall.
16. Always stop the engine when transporting and refu-
elling.
17. Do not empty the tank near open light, fire or
sparks. Smoking prohibited!
18. Do not use the power generator in a thunderstorm -
risk of lightning strike!
19. Provide a secure, level place for the power genera-
tor. Turning and tilting or changing location during
operation are forbidden.
20. Place the power generator at least 1 m away from
walls or connected devices.
21. Values specified in the technical data under sound
power level (LwA) and sound pressure level (LpA)
represent emission levels and are not necessarily
safe working levels. Since there is a correlation be-
tween emission and exposure levels, it cannot be
reliably used to determine any additional precau-
tionary measures that may be required. Factors in-
fluencing the current exposure level of the worker
include the characteristics of the workspace, other
noise sources, airborne noise, etc., such as the
number of machines and other adjacent processes
and the length of time an operator is exposed to the
noise. The permitted exposure level may also vary
from country to country.
Nevertheless, this information will enable the opera-
tor of the machine to make a better assessment of
the risks and hazards. If necessary, acoustical mea-
surements should be taken after installation to de-
termine the sound pressure level.
22. Observe the electrical safety regulations applicable
to the place where the power generator is used.
Electrical safety
1. Prior to use, the generator and its electrical equip-
ment (including lines and plug connectors) should
be checked to ensure that there are no defects.
2. The power generating unit must not be connected to
another power source such as the power supply of
energy supply companies. In special cases where a
reserve connection to existing electrical systems is
provided, this must only be carried out by a qualified
electrician who will take into account the differences
between the operated equipment using the public
mains and operation of the power generating unit. Ac-
cording to this part of ISO 8528, the differences in the
operating manual must be specified.
3. Protection against electric shocks depends on the
circuit breakers which are matched precisely to the
power generating unit. If a circuit breaker must be
replaced, this should be done using a circuit break-
er with the same rating and performance character-
istics.
4. Due to high mechanical loads, only durable rubber
hose lines (per IEC 60245-4) or equivalent equip-
ment should be used.
5. If extension leads or mobile distribution networks
are used, the resistance value must not exceed 1.5
Ω. As a guideline value, the total length of lines for
a cross-section of 1.5 mm² should not exceed 60 m,
and for a cross-section of 2.5 mm², 100 m should
not be exceeded.
WARNING
Comply with the electrical safety regulations applica-
ble to the place where the power generators are
used.
WARNING
Consider the requirements and precautionary mea-
sures in case of re-supply of a system by power gen-
erators depending on the protective measures of this
system and the applicable directives.
Handling fuel
ATTENTION
Use only E10 unleaded petrol as fuel.
DANGER
Danger to life!
Fuel is toxic and highly flammable.
• Only store fuel in containers (canisters) designed
for this purpose.
• The tank caps must always be properly screwed on
and tightened.
• For safety reasons, the fuel tanks and other fuel
caps must be replaced if damaged.
• Keep fuel away from sparks, open flames, perma-
nent flames, heat sources and other sources of igni-
tion.
Do not smoke!
• Refuel outdoors only and do not smoke while refuel-
ling.
• Before refuelling, switch off the combustion engine
and let it cool down.
• Fuel must be filled before starting the engine. While
the engine is running or immediately after switching
off the product, do not open the fuel filler cap or add
fuel.
www.scheppach.com
GB | 31