Problem
The drip tray is overfilled,
but the filling indicator
does not come up.
The cup tray wobbles on
the drip tray or is inclined.
The filter basket cannot
be removed from the por-
tafilter.
All button are illuminated
but the extraction function
does not work or not work
correctly.
EN
126
Possible Reasons
Water or splashes given
off by the steam wand
ran out.
The water system is lea-
king.
The filling indicator is
not inserted correctly or
missing.
The cup tray is in wrong
orientation. The filling indi-
cator is blocked.
The cup tray is in wrong
orientation.
The filling indicator is not
inserted correctly.
For operation, the filter
basket is engaged within
the portafilter via a bulge
at the side wall.
The selection dial is not
turned to standby cor-
rectly.
The water system is over-
heated.
You are using an unsuited
type of water.
The Easy Solution
Even when the selection dial is in the central stand-
by position (off), water and steam may escape. Thus,
always turn the steam wand to the drip tray or into a
vessel, when the steam wand is not in use. Wipe spilled
water immediately.
Immediately switch off and unplug the appliance. Get in
contact with your vendor for examination and repair.
Put the red float of the filling indicator onto the post
within the drip tray. Ensure that it can move freely up
and down.
Turn the cup tray by 180°. The large openings must lie
at the rear left side of the appliance. The cup tray must
lie stably and may not wobble. If required, turn the filling
indicator by 90°.
Turn the cup tray by 180°. The large openings must lie
at the rear left side of the appliance.
Turn the filling indicator by 90° and try again.
If you find it difficulty to get the filter basket out, use
a medium screw driver or the handle of a teaspoon for
carefully levering out the filter basket (see: 'Operation /
Inserting the Required Filter Basket').
Turn the selection dial at the left side of the group head
to the vertical standby position. Then try again.
Directly after using the steam function, the water system
is still on steam temperature. Simply wait, until the water
system reaches extraction temperature again. The extrac-
tion starts automatically.
Only use clear, cold tap water or low-mineral, non-carbo-
nated table water. Remove and empty the water tank.
Then refill the water tank and flush the water system
(see: 'Before First Use / Flushing the Water System').