Problem
The appliance does not
work
and/or
no steam, hot water, or
coffee is given off.
EN
124
Possible Reasons
A severe problem occur-
red.
The appliance is not live or
switched off.
The automatic shut-off has
been triggered.
Overheating of the pump,
the grinder, or the heating
block. The thermal cut-out
has been triggered.
The pump is working
with an unusual noi-
se: Not enough water
in the water tank or the
water tank is not installed
correctly.
Extracting espresso:
The selection dial is not
in the vertical standby
position.
Extracting espresso:
The filter basket or the
spouts of the portafilter
are clogged.
Hot water/steam
function: The steam
wand is clogged.
A severe problem occur-
red.
The Easy Solution
If an unpleasant smell persists after thoroughly purging
and cleaning the machine, switch off and unplug the
appliance. Get in contact with your vendor for examinati-
on and repair.
Switch on the appliance by pressing the power button.
Check, whether any buttons flash or illuminate. If not,
ensure that the power supply outlet is live by connecting
a lamp.
After max. 30 minutes of being idle, the appliance switches
off automatically. Press the power button to switch on the
appliance.
Unplug and leave the appliance cool down for 30-60
minutes. Thereafter, you may use the appliance again. If
not, get in contact with an authorized service centre for
examination and repair.
Immediately switch off the activated function!
Before operation, fill the water tank with a sufficient
amount of water (filling level between MIN and MAX).
Ensure that the water tank is installed correctly at the
rear of the appliance. Without violence push the water
tank down (see: 'Operation / Filling the Water Tank').
For extracting espresso, the selection dial must be turned
to the standby position. Otherwise, the appliance cannot
build up sufficient pressure at the group head.
Clean the filter basket and portafilter thoroughly (see:
'Care and Cleaning').
When the problem persists, get in contact with your ven-
dor for replacement.
Clean the steam wand (see: 'Care and Cleaning / Clea-
ning the Steam Wand').
Immediately switch off the appliance and unplug. Get in
contact with an authorized service centre for examination
and repair.