3: Tray 3
◦
D: Duplexer
◦
Recommended action
1.
To clear message, press the
2.
If the message reappears, turn the product off and then on.
3.
If the error persists, replace the DC controller PCA.
47.FC.YZ Printer calibration failed To continue, touch "OK"
Description
The product is unable to access or implement one of the image pattern files.
Y = calibration type, Z = event
47.FC.00 (event code): Color plane registration (CPR) image not found at system initialization
◦
47.FC.01 (event code): CPR store image failure
◦
47.FC.02 (event code): CPR image not found
◦
47.FC.03 (event code): CPR print engine execution failure
◦
47.FC.10 (event code): Consecutive Dmax Dhalf image not found at system initialization
◦
47.FC.11 (event code): Consecutive Dmax Dhalf store image failure
◦
47.FC.12 (event code): Consecutive Dmax Dhalf image not found
◦
47.FC.13 (event code): Consecutive Dmax Dhalf print engine execution failure
◦
47.FC.20 (event code): Error diffusion image not found at system initialization
◦
47.FC.21 (event code): Error diffusion store image failure
◦
47.FC.22 (event code): Error diffusion image not found
◦
47.FC.23 (event code): Error diffusion print engine execution failure
◦
47.FC.30 (event code): Drum speed adjustment Image not found at system initialization
◦
47.FC.31 (event code): Drum speed adjustment store image failure
◦
47.FC.32 (event code): Drum speed adjustment image not found
◦
47.FC.33 (event code): Drum speed adjustment print engine execution failure
◦
47.FC.40 (event code): Pulse width modulation image not found at system initialization
◦
47.FC.41 (event code): Pulse width modulation store image failure
◦
220
Chapter 2 Solve problems
OK
button.
ENWW