3.
Check the connector (J1) between the fuser and the product. If it is damaged, replace the fuser.
4.
If this product was previously serviced, check the connector (J61) on the DC controller PCA.
5.
If the error persists, replace the fuser.
W = B: High fuser temperature 3
1.
Remove and then reseat the fuser. Remove any residual paper in the product.
2.
Check the paper type setting using the product menus and in the print driver. Making sure that
they match and are correct for the type of paper being used.
3.
If this product was previously serviced, check the connector (J61) on the DC controller PCA.
4.
If the error persists, replace the fuser.
W = 1, Low fuser error temperature error
1.
Remove and then reseat the fuser.
2.
Check the paper type setting using the product menus and in the product driver. Make sure that
they match and are correct for the type of paper being used.
3.
If this product was previously serviced, check the connector (J61) on the DC controller PCA.
4.
If the error persists, replace the fuser.
W = 2, Fuser warm-up failure
1.
Reconnect the connector (J61) between the fuser and the DC controller PCA.
2.
Turn the product off. Remove the fuser, and then reinstall it.
3.
Replace the fuser wire harness.
4.
If the error persists, replace the fuser.
W = 3, High fuser temperature 1
1.
Remove and then reseat the fuser.
2.
Check the paper type setting using the product menus and in the product driver. Make sure that
they match and are correct for the type of paper being used.
3.
If this product was previously serviced, check the connector (J61) on the DC controller PCA.
4.
If the error persists, replace the fuser.
W = 4, Fuser power supply driving circuit error
1.
Remove and then reseat the fuser.
2.
If this product was previously serviced, check the connector (J61) on the DC controller PCA.
3.
If the error persists, replace the fuser.
ENWW