75│ORBEA

MOTOR HOUSING CABLING

See the Electrical Assist System Components section for more information on the pedelec system.
2

STEM AND HANDLEBAR CABLING OF SHIMANO COMPONENTS.

Rise uses handlebars from the OC Components Mountain Control range, which have a hole at the rear of the stem clamping area
and a hole at each end of the handlebars to allow internal routing through the handlebars of the electrical system's remote control
and the Di2 shift lever (aftermarket assemblies).
It is possible to mount non-OC handlebars without an internal cabling option in the handlebar. In this case, the cables of the elec-
trical system remote and the Di2 shift lever will be routed on the outside of the mounted handlebar.
Fitted Mountain Control range stems let the electrical system cables enter through a slot in the lower part of the stem to be routed
inside the OC handlebars. Depending on the assembly, a Shimano Di2 connector may be used inside the OC stem (see images be-
low for the various assembly options).
If the OC handlebars originally mounted on the bicycle is replaced, the new handlebars must allow internal routing of electronic
components. Otherwise, the cables of these components have to be positioned on the outside of the handlebars and stem.
If mounting a non-OC stem using the universal manifold for the HS02 headset, see the
manual, it may be necessary for the electrical system cabling and the Di2 connector to be left outside the stem if the newly in-
stalled stem does not have an internal cabling option.
Orbea does not guarantee the compatibility of components not specified in original Orbea assemblies. Check the feasibility of
assembling new components before installing them. Personal injury and property damage resulting from non-compatible com-
ponents and/or incorrect installation are not covered by the warranty conditions.
See the Electrical Assist System Components section for more information on the pedelec system.
5.2
7
6
*
to motor
1.
Rear derailleur housing (mechanical)
2.
XT Di2 derailleur (aftermarket assemblies)
1
3.
Rear brake line
3
4.
Dropper seatpost remote
5.1.
Cable harness RS Gen2. EP801/EP6 Motor connection
4
5.2.
Cable harness RS Gen2. Charging port
6.
EW-SS301 Speed sensor
7.
Shimano EW-SD300 1200 mm cable (to junction or display)
5.1
*See section Motor connections
** See section Di2 cabling on handlebars and stem
BLUE PAPER RISE HYDRO SL-LT • 2025
Orbea ICR Headset Standards
EN