Table of error messages
Code
Description
"E2"
Error, drive 1 motor
current too high
"E3"
Error, drive 2 motor
current too high
"E4"
Permitted duty cycle of
the system exceeded
"E5"
Blockage detected on
drive 1
"E6"
Blockage detected on
drive 2
"E7"
Error, intermediate
circuit undervoltage
"E8"
Error, drive 1 not
detected
"E9"
Difference between
drive 1 and drive 2 too
great
"E11"
Lag error between
controller 1 and drive 1
"E12"
Lag error between
controller 2 and drive 2
"E13"
External stop signal has
been set
"E21"
Safety edge not
connected or cable
break
"E22"
Safety edge actuated
during movement
"E23"
SPP collision due to
mechanical blockage
detected
"E24"
Overvoltage in the
intermediate circuit
Assembly instructions for the RK MultiControl II duo accu/DC control
Troubleshooting
If the error occurs frequently, check the system for
mechanical overload.
The maximum duty cycle of 20 % at 20 mins has been
exceeded. Wait until the error message disappears.
Check the system for mechanical blockages and remove them
as necessary.
The error message is active as long as the undervoltage is
detected on the control.
◼ Disconnect the mains cable
Check the power supply.
◼ Check the connections
◼ Carrying out initialization run
◼ Make sure that all drives move
◼ Check the system for mechanical load
◼ Carrying out initialization run
If the error message is still displayed, the control or the drive
could be faulty.
Drive could be faulty. Check the drive for mechanical strain.
Check the setting of the control and system for possible
errors.
Connect the safety edge or replace the cable.
◼ Reset the error code with a function key
◼ Free up the safety edge by moving opposite to the last
◼ Remove the blockage
direction
◼ Adjust the sensitivity of the SPP
Check the load on the drives.