6.4.2
Staff:
Protective equipment:
Prerequisite:
1.
Connecting the hand switch with 2 function keys
Assembly instructions for the RK MultiControl II duo accu/DC control
If the 3 m long extension cable is used for the drives, reduce the
travel speed (parameter 11
227).
Connecting the hand switch
◼ The mains cable must be disconnected from the power supply.
Connect the cable of the hand switch (Figure 23, position number 1) to the
hand switch interface HS.
Figure 23 - Connecting the hand switch
1.
Disconnect the cable of the hand switch from the hand switch
interface HS.
2.
Connect the cable of the hand switch to the hand switch interface
⇨ The LED display shows the error code "E38"
HS.
messages" on page 239.
3.
Press and hold both function keys for 5 seconds to reset the error.
◼ Assembly staff
◼ Protective clothing
◼ Safety shoes
⮱
"Table of parameters" on page
⮱
"Table of error
167