Inputs
I1 - I8*
I1
I2
I3
I4 - I6
I7
I8
RS485 A/B
U
digital input
* Input voltage level
** The voltage supply for digital inputs
3-bit mask for memory position
I6
0
0
0
0
1
1
1
1
160
◼ High: 5 - 30 VDC
Terminal Function
◼ Low: 0 - 2 VDC
1 - 8
UP: When the high level is active, a movement is made towards
1
the maximum position.
2
DOWN: When the high level is active, a movement is made
towards the minimum position.
3
Enabling of action from the 3-bit mask (Inputs 4 - 6)
4 - 6
3-bit mask for memory position
7
Speed (f/s): Changes the speed (fast/slow) of the system. If the
high level is active, creep speed is activated.
The speed is set using parameter 17
8
Reset error: Resets the active status of an error if possible.
9, 10
Control-BUS A/B – connected to the control via control BUS
cable
**
11
Logic V+, 12 VDC, max. 40 mA – connected to the control via
control BUS cable
12
GND – connected to the control via control BUS cable
Inputs
I5
I4
0
0
Start initialization run
0
1
Move to memory position 1
1
0
Move to memory position 2
1
1
Move to memory position 3
0
0
Move to memory position 4
0
1
Move to memory position 5
1
0
Move to memory position 6
1
1
Move to memory position 7
Assembly instructions for the RK MultiControl II duo accu/DC control
"Table of parameters" on page 227.