Pin
1
2
3
4
5
6
*Please note: The RK MultiControl II duo DC control comes with the 6-pin DC connecting
cable with one open cable end for connecting to an external voltage source.
**Please note: The battery mount is required for connecting the approved batteries (not
included with the controls).
4.5.6
Inputs
Assembly instructions for the RK MultiControl II duo accu/DC control
Function
Description
GND
Supply voltage GND
◼ Supply voltage V+, max. 10 ADC
I2C
Communication BUS
◼ 24 VDC* (± 2 VDC) MultiControl II duo DC (QSTxxDxxxxxx)
◼ 28 VDC** (see Section 4.3.2 on page 149 for approved
V+
I2C
Communication BUS

Connection configuration - IO interface module

Figure 18 - IO interface module inputs
batteries) RK MultiControl II duo accu (QSTxxGxxxxxx).
Connection of the batteries using the battery mount.
(
see Section "Battery" on page 149)