Assembly instructions for the RK MultiControl II duo accu/DC control
8.5.4.3
"Collision detection (SPP)" menu
Premium version
This function is only available with the premium version.
The Multilift I and Multilift Synchro cannot be used with the
premium version of the MultiControl II duo accu/DC control.
Collision detection (SPP)
This function includes the "Smart Product Protection" (SPP)
technology developed by RK Rose+Krieger GmbH, and ensures
that the risk of material damage for the customer's application
is reduced.
Protection is provided not just for the connected drives, but also
for the adjoining set-up as a whole.
The collision detection does not meet the requirements of the
regulations for personal safety (personal protection).
The collision detection is deactivated at the factory.
The collision detection can only detect obstacles after an acceleration phase (the
default setting is approximately 1 second).
After an obstacle has been detected, the movement stops and movement in the
last direction of travel is blocked.
The system first has to be freed up by moving it in the opposite direction. Movement
of the system is then enabled again.
◼ The main menu for the hand switch is displayed.
Prerequisite:
187
Selecting the "Collision detection (SPP)" menu
Select the menu via "Control" → "Stop functions" → "Collision
1.
detection (SPP)" (Figure 81).
⮱
Section 8.3 on page
211