Connecting the stop input
1.
2.
Activating the stop input
3.
172

Connecting the operator's stop input

Figure 26 - Connecting the BUS cable (control)
◼ The mains cable must be disconnected from the power supply.
Connect the BUS cable (Figure 26, position number 1) to the DATA interface
on the control.
Connect the exposed wires of the BUS cable to the operator's stop input
switch between 12 VDC and sensor input 4 in accordance with the following
table:
Pin
5
8
⇨ Connection and activation of the operator's stop input is complete.
Activate the "stop input" function
If the stop input switch is actuated whilst a movement is being
performed, the drives are stopped as quickly as possible.
If the stop input switch is deactivated
be moved again.
Assembly instructions for the RK MultiControl II duo accu/DC control
◼ Qualified electrician
◼ Protective clothing
◼ Safety shoes
Wire colour
Pink
Blue
Page 210.
Function
12 VDC
Sensor input 4
Page 210, the drives can