Herunterladen Inhalt Inhalt Diese Seite drucken

Drive Slot; Power Supply Slot - Phoenix Mecano Rk Rose+Krieger Rk Multicontrol Ii Duo Accu/Dc Control Montageanleitung

Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

4.5.4
Pin
1
2
3
4
5
6
7
8
4.5.5
158

Drive slot

Figure 16 - Drive slot contacts
◼ Activation of the drive (output)
Function
Description
◼ 0 - 28.5 VDC
Motor +
◼ Signal contact input
◼ Contact type: NC
Bottom limit
◼ If the limit switch is not actuated, there is +12 VDC
switch
◼ In the final position the connected limit switch contact is
◼ Hall sensor signal inputs
+ 12 VDC
Supply to Hall sensors and limit switches (output)
◼ Hall sensor output type: open collector
Hall sensor A
◼ Signal contact input
Hall sensor B
◼ Contact type: NC
Top limit switch
◼ If the limit switch is not actuated, there is +12 VDC
◼ In the final position, the connected limit switch contact is
open
◼ Activation of the drive (output)
GND
Supply to Hall sensors (output)
◼ 0 - 28.5 VDC
Motor -

Power supply slot

Figure 17 - Power supply slot contacts
Assembly instructions for the RK MultiControl II duo accu/DC control
open

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis