Herunterladen Inhalt Inhalt Diese Seite drucken

Phoenix Mecano RK Rose+Krieger RK MultiControl II duo accu/DC control Montageanleitung Seite 169

Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

Connecting the safety edge
Staff:
Protective equipment:
Prerequisite:
1.
2.
Activating the safety edge
3.
Information on selection and installation
Depending on the design and manufacturer, safety edges can have different properties.
When selecting a safety edge, pay attention to the following properties:
Assembly instructions for the RK MultiControl II duo accu/DC control
◼ The mains cable must be disconnected from the power supply.
Connect the BUS cable (Figure 24, position number 1) to the DATA interface
on the control.
Connect the exposed wires of the BUS cable to the operator's safety edge
between GND and sensor input 1 in accordance with the following table:
Pin
1
4
⇨ Connection and activation of the operator's safety edge is complete.
Activate the "safety edge" function
If the "safety edge" function is activated and the operator's safety
edge is actuated, the connected drives stop as quickly as possible.
If the safety edge is actuated while the drives are being moved, the
system can be freed up by moving it in the opposite direction at
reduced speed. If the safety edge is actuated while at a standstill,
the safety edge will need to be released again before moving the
drives.
◼ Actuation path
◼ Overrun distance
◼ Terminating resistor
◼ Switching resistor
◼ Qualified electrician
◼ Protective clothing
◼ Safety shoes
Wire colour
Brown
Grey
Function
-
Sensor input 1
Page 208.