Pin
1
2
3
4
5
6
The signal contact inputs UP and DOWN can be switched to +12 VDC by buttons (not
switches) to operate the drives.
4.5.3
Pin
1
2
3
4
5
6
7
8
Assembly instructions for the RK MultiControl II duo accu/DC control
Function
Description
GND
-
◼ Signal contact input
RS485 B
Control BUS
◼ Contact type: NO (high active)
UP
◼ Voltage: maximum 12 VDC
◼ 12 V ± 10 %
◼ Maximum 20 mA
12 VDC
◼ Signal contact input
RS485 A
Control BUS
◼ Contact type: NO (high active)
DOWN
◼ Voltage: maximum 12 VDC
DATA interface
Figure 15 - DATA interface contacts
Function
Description
GND
-
RS485 B
Serial interface for communication between
the controls (sync BUS)
Sensor 2
No set function
◼ 12 V ± 10 %
Sensor 1
Safety edge
◼ Maximum 20 mA
12 VDC
RS485 A
Sync BUS
Sensor 3
No set function
Sensor 4
External stop input
⮱
Page 168
⮱
Page 172
Wire colour
Brown
Green
White
Pink
Yellow
Grey
Wire colour
Brown
Green
White
Grey
Pink
Yellow
Black
Blue