212
Selecting the direction of travel
2.
Select the direction of travel "Extend" or "Retract" (in this case:
"Extend", Figure 82).
Activating collision detection (SPP)
3.
Set the sensitivity of collision detection for the selected direction of travel
(in this case: "sensitivity high" Figure 83):
High: Detection threshold 50 mA (default value for Multilift II)
Medium: Detection threshold 150 mA (default value for Multilift II)
Low: Detection threshold 250 mA (default value for Multilift II)
User-defined: Adjustable detection threshold from 0 - 4000 mA
⇨ Collision detection (SPP) is active.
Assembly instructions for the RK MultiControl II duo accu/DC control
Figure 81 - Selecting a menu
Figure 82 - Selecting the direction of travel
When drive group management is activated, set collision
detection (SPP) separately for each drive group.