Terminal X4, torque transducer - TMC
RA
RB
TX
RX
7.4
Supply voltage
The module must be operated with a separated extra-low voltage (nominal supply volt
age 18 to 30 V DC ), which usually supplies one or more consumers within a test bench.
Should the device be operated on a DC voltage network, additional precautions must be
taken to discharge excess voltages.
7.4.1
Operating multiple TIM-EC modules
A maximum of 4 TIM-EC modules can be operated with 4 torque transducers in master
mode/individual mode with only one supply point. The left interface module should al
ways be selected for the supply point in this operating mode.
Notice
Multi-point supply of the devices operating in series is not permitted.
14
4
Not in use
5
Not in use
Pin
Assignment
1
DGND (digital GND), color code purple
2
RS422-RA, color code red
3
RS422-RB, color code white
4
RS‐232‐TX, color code gray
5
RS‐232‐RX, color code green
TIM-EC
ELECTRICAL CONNECTION