Table of errors in torque
CRC5-Error in
sequence
[dynamic]
Measured value not
sent (stator has
detected an error or
transmission is
defective)
[dynamic]
Linearization error
[static]
Measured value
overflow or underflow
[dynamic]
Table of errors in speed
Speed system not
present [static]
Speed value overflow
or underflow
[dynamic]
Speed system cannot
be sufficiently
determined
[static]
Compatibility error
[static]
40
During the transmission from torque transducer to TIM-EC, a
CRC error was detected in more than 5 errors in direct
sequence (otherwise the preceding old correct value is taken)
If a measured value is not sent at all, the error state must be
assumed immediately. If the stator can be accessed, the
device errors are also updated.
Linearization is active, but rotor serial number is different to
that in the device TIM-EC.
The limit for T40 is +/- 120% the nominal (rated) torque.
Web browser selection set to "determine automatically from
transducer" and the torque transducer is not outputting any
information about the speed system or a speed system is not
present.
Speed value exceeds the maximum value (nominal (rated)
speed + 105%)
Web browser selection set to "determine automatically from
transducer" and the torque transducer is not outputting any
information about the properties Pulses/Rev., Max. Speed,
Type.
Or the selection is set to "Manual" and the maximum speed is
set to 0 or "
".
The stator and rotor speed systems are not compatible in
physics or version.
TIM-EC