Herunterladen Inhalt Inhalt Diese Seite drucken

Select The Best Location - Panasonic ADC0309H3E5 Installationshandbuch

Luft/wasser-hydromodul + speicher
Vorschau ausblenden Andere Handbücher für ADC0309H3E5:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 159
Attached accessories
No.
Accessory part
Qty. No.
Adjustable Feet
4
1
4
Reducing Adapter
1
2
5
Drain Elbow
1
3
Optional Accessories
No.
Accessories part
6
Optional PCB (CZ-NS4P)
7
Network Adaptor (CZ-TAW1)
Dimension Diagram
598
FRONT VIEW
60
478
60
Adjustable Feet
BOTTOM VIEW
Tube Connector Function
Water Inlet (From Space Heating/Cooling)
a
Water Outlet (To Space Heating/Cooling)
b
Cold Water Inlet (Domestic Hot Water Tank)
c
Hot Water Outlet (Domestic Hot Water Tank)
d
Refrigerant Gas
e
Refrigerant Liquid
f
Domestic Hot Water Tank Discharge (Drain Tap)
g
Type: Ball Valve
Pressure Relief Valve Drainage
h
Drain Water Hole
i
Weight (kg)
Model
Capacity (L)
Empty
ADC0309H3E5
185
120

SELECT THE BEST LOCATION

1
Install the Tank Unit in indoors with frost free weather proof
location only.
Must install on a fl at horizontal and solid hard surface.
There should not be any heat source or steam near the
Tank Unit.
A place where air circulation in the room is good.
A place where drainage can be easily done (e.g. Utility room).
A place where Tank Unit's operation noise will not cause
discomfort to the user.
Field Supply Accessories (Optional)
No.
Accessory part
Qty.
Packing
i
1
ii
Remote Controller
iii Mixing valve
Cover
iv Pump
1
v
vi Outdoor sensor
vii Zone water sensor
viii Zone room sensor
ix Solar sensor
Qty.
  It is recommended to purchase the fi eld supply accessories listed in above table.
1
1
Tube Position Diagram
717
e
f
h
229
159
133
102
SIDE VIEW
1
position
Connector Size
7/8-14UNF
7/16-20UNF
Full
305
Part
Electromotoric Actuator
2-way valve kit
*Cooling model
2-port Valve
Room thermostat
Wired
Wireless
Buffer tank sensor
Main Components Diagram
a
c
9
7
0
d
c
a
d
b
g
j
475
380
g
300
b
k
1 Remote Controller
2 Water Pump
3 Control Board Cover
4 Main PCB
5-1
5-2
6 Water Filter Set
427
i
7 Heater Assembly
8 3-Way Valve (Not Visible)
9 Overload Protector (Not Visible)
0 Expansion Vessel (Not Visible)
a Air Purge Valve
b Pressure Relief Valve
c Flow Sensor
d Water Pressure Gauge
R 1¼"
e Front Plate
R 1¼"
f Top Plate
R ¾"
g Right Plate
h Left Plate
R ¾"
i Rear Plate
j Tank Sensor (Not Visible)
k Safety Relief Valve
Rc 1/2"
---
---
A place where Tank Unit is far from door way.
A place where accessible for maintenance.
Ensure to keep minimum distance of spaces as illustrated
below from wall, ceiling, or other obstacles.
A place where fl ammable gas leaking might not occur.
Secure the Tank Unit to prevent it being knocked over
accidentally or during earthquakes.
Model
Specifi cations Maker
SFA21/18
AC230V
VVI46/25
PAW-A2W-RTWIRED
AC230V
PAW-A2W-RTWIRELESS
167032
AC230V
Yonos 25/6
AC230V
PAW-A2W-TSBU
PAW-A2W-TSOD
PAW-A2W-TSHC
PAW-A2W-TSRT
PAW-A2W-TSSO
f
8
9
1
2
3
4
e
h
5-1
5-2
6
Single Phase RCCB/ELCB (Main Power)
Single Phase RCCB/ELCB (Backup Heater)
Siemens
Siemens
Caleffi
Wilo
i
3

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis