Attached accessories
No.
Accessory part
Qty. No.
Adjustable Feet
4
1
3
Drain Elbow
1
2
4
Optional Accessories
No.
Accessories part
5
Optional PCB (CZ-NS4P)
Network Adaptor (CZ-TAW1) and
6
Extension Cable (CZ-TAW1-CBL)
Dimension Diagram
597
FRONT VIEW
37
526
37
Adjustable
Feet 1
position
BOTTOM VIEW
Tube Connector Function
Water Inlet (From Space Heating/Cooling)
a
Water Outlet (To Space Heating/Cooling)
b
Cold Water Inlet (Domestic Hot Water Tank)
c
Hot Water Outlet (Domestic Hot Water Tank)
d
Refrigerant Gas
e
Refrigerant Liquid
f
Domestic Hot Water Tank Discharge (Drain Tap)
g
Type: Ball Valve
Drain Water Hole
h
Model
Capacity (L)
Empty
WH-ADC1216H6E5C
185

SELECT THE BEST LOCATION

1
Before choosing the installation site, obtain user approval.
Install the Tank Unit in indoors with frost free weather proof
location only.
Must install on a fl at horizontal and solid hard surface.
There should not be any heat source or steam near the
Tank Unit.
A place where air circulation in the room is good.
A place where drainage can be easily done (e.g. Utility room).
A place where Tank Unit's operation noise will not cause
discomfort to the user.
A place where Tank Unit is far from door way.
Field Supply Accessories (Optional)
Accessory part
Qty.
Packing
1
Remote Controller
Cover
1
Qty.
1
  It is recommended to purchase the fi eld supply accessories listed in above table.
1
Tube Position Diagram
599
b
a
SIDE VIEW
435
90
254
90
75100
TOP VIEW
Weight (kg)
Full
101
286
No.
Part
Electromotoric Actuator
2-way valve kit
i
*Cooling model
2-port Valve
Room thermostat
Wired
ii
Wireless
iii Mixing valve
iv Pump
v
Buffer tank sensor
vi Outdoor sensor
vii Zone water sensor
viii Zone room sensor
ix Solar sensor
Main Components Diagram
e
f
c
d
23
g
1 Remote Controller
h
2 Water Pump
3 Control Board Cover
4 Control Board
5 Main PCB
6-1
Single Phase RCCB/ELCB (Main Power)
6-2
Single Phase RCCB/ELCB (Backup Heater)
7 Magnetic Water Filter Set
8 Heater Assembly
Connector Size
9 3-Way Valve
R 1¼"
0 Overload Protector (Not Visible)
R 1¼"
a Expansion Vessel
R ¾"
b Air Purge Valve
c Pressure Relief Valve
R ¾"
d Flow Sensor
7/8-14UNF
e Water Pressure Gauge
5/8-18UNF
f Front Plate
g Top Plate
Rc 1/2"
h Right Plate
---
i Left Plate
j Rear Plate
k Tank Sensor (Not Visible)
l Safety Relief Valve
m Bushing (4 pieces)
A place where accessible for maintenance.
Ensure to keep minimum distance of spaces as illustrated
below from wall, ceiling, or other obstacles.
A place where fl ammable gas leaking might not occur.
Secure the Tank Unit to prevent it being knocked over
accidentally or during earthquakes.
Please avoid installations which expose the Tank Unit to any of the
following conditions:
Extraordinary environment conditions; installation in frost or
exposure to unfavorable weather conditions.
Voltage input exceeding the specifi ed voltage.
Model
Specifi cations Maker
SFA21/18
AC230V
VVI46/25
PAW-A2W-RTWIRED
AC230V
PAW-A2W-RTWIRELESS
167032
AC230V
Yonos 25/6
AC230V
PAW-A2W-TSBU
PAW-A2W-TSOD
PAW-A2W-TSHC
PAW-A2W-TSRT
PAW-A2W-TSSO
1
15
17
12
14
7
10
8
9
20
21
19
16
Siemens
Siemens
Caleffi
Wilo
4
5
6-1
6-2
3
11
2
13
18
22
3

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis