Herunterladen Inhalt Inhalt Diese Seite drucken

Select The Best Location - Panasonic UX09 E5 series Installationshandbuch

Vorschau ausblenden Andere Handbücher für UX09 E5 series:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 41
Attached accessories
No.
Accessory part
Qty. No.
Adjustable Feet
1
3
4
Drain Elbow
2
1
Dimension Diagram
598
400
Anode Bar
FRONT VIEW
60
478
60
Adjustable Feet
Tube
Connector
a
BOTTOM VIEW
b
c
d
e
f
g
h
i
Model
ADC1216*E5*

SELECT THE BEST LOCATION

1
Install the Tank Unit in indoors with frost free weather proof
location only.
Must install on a fl at horizontal and solid hard surface.
There should not be any heat source or steam near the Tank Unit.
A place where air circulation in the room is good.
A place where drainage can be easily done (e.g. Utility room).
Required space for installation
(Unit : mm)
Field Supply Accessories
No.
Accessory part
Qty.
Packing
1
  It is recommended to purchase the fi eld supply accessories from the specifi c maker whom listed
Tube Position Diagram
717
SIDE VIEW
1
position
Function
Water Inlet (From Space Heating/Cooling)
Water Outlet (To Space Heating/Cooling)
Cold Water Inlet (Domestic Hot Water Tank)
Hot Water Outlet (Domestic Hot Water Tank)
Refrigerant Gas
Refrigerant Liquid
Domestic Hot Water Tank Discharge (Drain Tap)
Type: Ball Valve
Pressure Relief Valve Drainage
Drain Water Hole
Weight (kg)
Capacity (L)
Empty
Full
185
137
322
Transport and Handling
Be careful during transportating the unit so that it is not damaged by impact.
Only remove the packaging material once it has reached it is desired installation location.
It may need three or more people to carry out the installation work. The weight of Tank Unit might cause injury
if carried by one person.
The Tank Unit can be transported either in vertical or horizontal.
- If it transported in horizontal, make sure Front of packaging material (printed with
"FRONT") must facing upwards.
- If it transported in vertical, use the hand holes on sides,
slide and move to the desired location.
Fix the Adjustable Feet 1 , if the Tank unit installed on a
uneven surface.
Part
Qty.
Electromotoric Actuator
i
2-way Valve Kit
1
ii
Room Thermostat
1
Programmable Type
in above table.
Main Components Diagram
b
a
0
9
8
f
e
d
c
b
a
7
h
g
475
380
m
300
230
159
102
6
1 Control Panel
2 Water Pump
3 Control Board Cover
4 PCB, Printed Circuit Board
427
5-1
i
5-2
6 Water Filter Set
7 Anode Bar (Not Visible)
Connector Size
8 Heater Cover
9 Heater Assembly
R 1¼"
0 3-Way Valve
R 1¼"
a Overload Protector (Not Visible)
R ¾"
b Expansion Vessel (Not Visible)
R ¾"
c Air Purge Valve
d Pressure Relief Valve
7/8-14UNF
e Flow Switch
5/8-18UNF
f Water Pressure Gauge
Rc 1/2"
g Top Front Plate
h Bottom Front Plate
i Top Plate
---
j Right Plate
---
k Left Plate
l Rear Plate
m Tank Sensor (Not Visible)
A place where Tank Unit's operation noise will not cause discomfort
to the user.
A place where Tank Unit is far from door way.
A place where accessible for maintenance.
Ensure to keep minimum distance of spaces as illustrated below
from wall, ceiling, or other obstacles.
A place where fl ammable gas leaking might not occur.
Secure the Tank Unit to prevent it being knocked over accidentally
or during earthquakes.
Model
Specifi cations Maker
SFA21/18
AC230V
2-port Valve
VVI46/25
Analog Type
RAA20
AC230V
REV200
1
k
2
3
g
4
h
5-1
5-2
Single Phase RCCB/ELCB (Main Power)
Single Phase RCCB/ELCB (Backup Heater)
Hold
Hold
Hold arrow section
to slide and move
Siemens
--
Siemens
Siemens
i
l
j
3

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis