Dimension Diagram

1283
39
Front view
150
980
28
Bottom view
Drain hose connector
7
Power Supply 1
Power Supply 2
Remote Control

SELECT THE BEST LOCATION

1
Install the Mono bloc unit in outdoor locations only.
Avoid installations in areas where the ambient temperature may drop
below -20°C.
The Mono bloc unit must be installed on a fl at, solid surface.
A Place removed from any heat source or steam which may effect the
operation of the Mono bloc unit.
A place where air circulation is good.
A place where drainage can be easily done.
A place where Mono bloc unit's operation noise will not cause
discomfort to the user.
A place which is accessible for maintenance.
Ensure to keep minimum distance of spaces as illustrated below from
wall, ceiling, or other obstacles.
A place where fl ammable gas leaking might not occur.
A place where the Mono bloc unit's piping and wiring lengths come
within reasonable ranges.
If an awning is built over the unit to prevent direct sunlight or rain, be
careful that heat radiation from the condenser is not obstructed.
320
45
45
45
50
Rear view
83.5
Water Outlet Pipe
Water Inlet Pipe
Optional cord / cable :-
3-way Valve cable (3 x min 0.5mm
Booster Heater cord (3 x min 1.5mm
Room Themostat cable (4 or 3 x min 0.5mm
Tank OLP cable (2 x min 0.5mm
Tank Sensor cable (2 x min 0.3mm
External Controller cable (2 x min 0.5mm
Solar Three-way Valve cable (3 x min 0.5mm
Solar Pump Station cable (2 x min 0.5mm

Main Components

9
Component name
1 PCB
2 Pressure relief valve
3 Flow switch
4 Pressure gauge
5 Water pump
6 RCCB
7 Bushing
8 Cabinet front plate
9 Cabinet top plate
0 Overload protector
a Heater assembly
b Expansion vessel
2
)
c Cover
2
)
Type
d Air purge valve
2
)
designation
2
)
60245 IEC
2
)
57 or heavier
2
)
blockage directions. For better ventilation
cord/ cable
2
)
& multiple-outdoor installation, please
2
)
consult authorized dealer/specialist.
Do not place any obstacles which may cause a short circuit of the
discharged air.
Avoid installing the Mono bloc unit at a location where suction side
may be exposed directly to wind.
If Mono bloc unit installed near sea, region with high content of
sulphur or oily location (e.g. machinery oil, etc.), it lifespan maybe
shorten.
When installing the product in a place where it will be
affected by typhoon or strong wind such as wind blowing
between buildings, including the rooftop of a building and
a place where there is no building in surroundings, fi x the
product with an overturn prevention wire, etc. (Overturn
prevention fi tting model number: K-KYZP15C)
When connecting solar pump station cable between Mono bloc unit
and solar pump station, the distance between both apparatuses shall
be 2 ~ 8 meters and the maximum length of 10 metres only.
Failure to do so may lead to abnormal operation to the system.
6
2
14
(VIEW
WITHOUT
3
COVER)
4
A
11
7
b
12
a
5
10
10
DETAIL Ag
DETAIL Ah
FOR
FOR
WH-MHF12G6E5
WH-MHF09G3E5
(WITHOUT OLP
(WITHOUT OLP
COVER)
COVER)
View without cabinet top plate
Connector name
g
Water inlet
h
Water outlet
It is advisable to avoid more than 2
1
8
13
3

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Wh-mhf12Whmxc09g3e5

Inhaltsverzeichnis